Steel Flexible Conduit
|
|
CAT#
|
Size
|
Internal Diameter
Min/Max
(mm)
|
External Diameter
Min/Max
(mm)
|
Min. Bend
Radlus
(mm)
|
Coil
Packing
(m)
|
SLDX210
|
3/8"
|
12.3/12.8
|
15.7/16.2
|
30
|
50
|
SLDX220
|
1/2"
|
15.8/16.3
|
19.2/19.7
|
43
|
50
|
SLDX230
|
3/4"
|
20.7/21.2
|
24.5/25.1
|
50
|
50
|
SLDX240
|
1"
|
26.4/26.8
|
30.4/31.0
|
57
|
50
|
SLDX250
|
1-1/4"
|
34.7/35.4
|
39.6/40.3
|
70
|
50
|
SLDX260
|
1-1/2"
|
40.0/40.6
|
45.2/45.8
|
80
|
25
|
SLDX270
|
2"
|
51.3/51.9
|
56.5/57.1
|
95
|
25
|
SLDX280
|
2-1/2"
|
63.0/63.6
|
70.2/70.8
|
140
|
15
|
SLDX290
|
3"
|
78.0/78.7
|
85.2/85.9
|
150
|
10
|
SLDX200
|
4"
|
101.6/102.6
|
108.5/109.5
|
190
|
10
|
|
鈼忓摖teel 閾夸骏xible conduit offers high 閾夸骏xibility and mechanicalstrength where low level ingress protection is sufficient.
鈼忓摗ype SLDX is widely used in dry, internal installations e.g.Under閾夸抗or wiring whereas. Fit for connectors of SL020,SL023, SL031 type
|
|
|
CAT# |
CAT#
|
Size
|
Internal
Diameter
Min/Max(mm)
|
External
Diameter
Min/Max(mm)
|
Min. Bend
Radlus
(mm)
|
Coil
Packing
(m)
|
SLDX-PG7
|
SLDX-SS-PG7
|
PG7
|
9.2/9.5
|
12.6/12.9
|
30
|
50
|
SLDX-PG9
|
SLDX-SS-PG9
|
PG9
|
10.6/10.9
|
14.0/14.3
|
35
|
50
|
SLDX-PG11
|
SLDX-SS-PG11
|
PG11
|
13.6/13.9
|
16.8/17.1
|
38
|
50
|
SLDX-PG13
|
SLDX-SS-PG13
|
PG13
|
15.6/15.9
|
19.5/19.8
|
40
|
50
|
SLDX-PG16
|
SLDX-SS-PG16
|
PG16
|
17.3/17.6
|
21.4/21.7
|
45
|
50
|
SLDX-PG21
|
SLDX-SS-PG21
|
PG21
|
22.7/23.1
|
27.3/27.6
|
50
|
25
|
SLDX-PG29
|
SLDX-SS-PG29
|
PG29
|
30.8/31.2
|
35.9/36.2
|
58
|
25
|
SLDX-PG36
|
SLDX-SS-PG36
|
PG36
|
39.5/39.9
|
46/46.3
|
90
|
25
|
SLDX-PG48
|
SLDX-SS-PG48
|
PG48
|
51/51.5
|
57.4/57.8
|
100
|
25
|
|
鈼忓摖teel 閾夸骏xible conduit offers high 閾夸骏xibility and mechanical strength where low level ingress protection is sufficient.
鈼忓摗ype SLDX-PG is widely used in dry, internal installations e.g. Under閾夸抗or wiring whereas
鈼忓摗ype SLDX-SS-PG is particularly suitable for wet or corrosive environment or severe temperature 閾垮乧tuations
|
|
|
CAT#
|
Size
|
Internal
Diameter
Min/Max(mm)
|
External
Diameter
Min/Max(mm)
|
Min. Bend
Radlus
(mm)
|
Coil
Packing
(m)
|
Thickness of Band
|
SLBR-U
mm)
|
SEMT
(mm)
|
SLBR-U210
|
3/8"
|
9.52/9.98
|
14.22/15.49
|
50
|
250
|
0.3x9.5
|
0.55x9.5
|
SLBR-U220
|
1/2"
|
15.87/16.38
|
21.84/23.36
|
76
|
100
|
0.35x9.5
|
0.45x12.7
|
SLBR-U230
|
3/4"
|
21.62/21.20
|
26.54/28.06
|
100
|
100
|
0.35x9.5
|
0.45x12.7
|
SLBR-U240
|
1"
|
25.4/26.4
|
33.02/35.05
|
125
|
50
|
0.4x12.7
|
0.6x12.7
|
SLBR-U250
|
1-1/4"
|
31.75/33.02
|
39.37/41.40
|
158
|
50
|
0.45x12.7
|
0.6x12.7
|
SLBR-U260
|
1-1/2"
|
38.10/40.0
|
46.99/49.53
|
180
|
25
|
0.5x17
|
0.6x21.2
|
SLBR-U270
|
2"
|
50.8/52.83
|
59.69/62.23
|
250
|
25
|
0.5x17
|
0.6x21.2
|
SLBR-U280
|
2-1/2"
|
63.5/-
|
72.64/77.72
|
320
|
25
|
0.6x21.2
|
0.6x21.2
|
SLBR-U290
|
3"
|
76.2/-
|
85.34/90.42
|
380
|
25
|
0.6x21.2
|
0.6x21.2
|
SLBR-U219
|
3-1/2"
|
88.9/-
|
98.04/103.12
|
450
|
25
|
0.6x21.2
|
0.6x21.2
|
SLBR-U200
|
4"
|
101.6/-
|
110.74/115.84
|
500
|
25
|
0.6x21.2
|
0.6x21.2
|
|
鈼忓摗ype SLBR-U is widely used in dry, internal installations e.g. Under閾夸抗or wiring whereas. Using thicker material which offershigher tensile strength.
鈼忓挾it for connectors of SL120 type
|
|