Earth contact position
Rated current(A)
|
Pole
|
4h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
118
|
146
|
b |
82
|
100
|
c |
47 |
63 |
d |
6-15
|
10-20
|
sw
|
38
|
50
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-P013-4/HJ-P023-4
Current(A):16A,32A
Voltage(V):110-130V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
118
|
146
|
b |
82
|
100
|
c |
47 |
63 |
d |
6-15
|
10-20
|
sw
|
38
|
50
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-P013/HJ-P023
Current(A):16A,32A
Voltage(V):220-240V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
4
|
Dimension(mm)
|
a |
124
|
146
|
b |
88
|
100
|
c |
53 |
63 |
d |
6-15
|
10-20
|
sw
|
38
|
50
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-P014/HJ-P024
Current(A):16A,32A
Voltage(V):380-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
5
|
Dimension(mm)
|
a |
131
|
152
|
b |
95
|
106
|
c |
61 |
70 |
d |
8-16
|
10-20
|
sw
|
42
|
50
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-P015/HJ-P025
Current(A):16A,32A
Voltage(V):220-380V~
240-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
4h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
149
|
163
|
b |
96
|
107
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-S113-4/HJ-S123-4
Current(A):16A,32A
Voltage(V):110-130V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
149
|
163
|
b |
96
|
107
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-S113/HJ-S123
Current(A):16A,32A
Voltage(V):220-240V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
4
|
Dimension(mm)
|
a |
150
|
163
|
b |
101
|
107
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-S114/HJ-S124
Current(A):16A,32A
Voltage(V):380-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
5
|
Dimension(mm)
|
a |
153
|
163
|
b |
103
|
113
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-S115/HJ-S125
Current(A):16A,32A
Voltage(V):220-380V~
240-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
4h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
127
|
159
|
b |
75
|
90
|
c |
6-15
|
10-20
|
d |
51 |
66 |
sw
|
38
|
50
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-C213-4/HJ-C223-4
Current(A):16A,32A
Voltage(V):110-130V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
127
|
159
|
b |
75
|
90
|
c |
6-15
|
10-20
|
d |
51 |
66 |
sw
|
38
|
50
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-C213HJ-C223
Current(A):16A,32A
Voltage(V):220-240V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
4
|
Dimension(mm)
|
a |
135
|
159
|
b |
80
|
90
|
c |
6-15
|
10-20
|
d |
57 |
66 |
sw
|
38
|
50
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-C214/HJ-C224
Current(A):16A,32A
Voltage(V):380-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
5
|
Dimension(mm)
|
a |
142
|
159
|
b |
82
|
97
|
c |
8-16
|
10-20
|
d |
64 |
72 |
sw
|
42
|
50
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-C215/HJ-C225
Current(A):16A,32A
Voltage(V):220-380V~
240-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
4h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
80
|
80
|
b |
98
|
98
|
c |
60
|
60
|
d
|
73
|
73
|
e |
37 |
45 |
f |
50 |
57 |
g |
57 |
72 |
h |
62 |
81 |
i |
5.5 |
5.5 |
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-S313-4/HJ-S323-4
Current(A):16A,32A
Voltage(V):110-130V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
80
|
80
|
b |
98
|
98
|
c |
60
|
60
|
d
|
73
|
73
|
e |
37 |
45 |
f |
50 |
57 |
g |
57 |
72 |
h |
62 |
81 |
i |
5.5 |
5.5 |
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-S313/HJ-S323
Current(A):16A,32A
Voltage(V):220-240V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
4
|
Dimension(mm)
|
a |
80
|
80
|
b |
98
|
98
|
c |
60
|
60
|
d
|
73
|
73
|
e |
40 |
45 |
f |
46 |
57 |
g |
63 |
72 |
h |
70 |
81 |
i |
5.5 |
5.5 |
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-S314/HJ-S324
Current(A):16A,32A
Voltage(V):380-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
4
|
Dimension(mm)
|
a |
80
|
80
|
b |
98
|
98
|
c |
60
|
60
|
d
|
73
|
73
|
e |
43 |
47 |
f |
45 |
55 |
g |
70 |
78 |
h |
78 |
88 |
i |
5.5 |
5.5 |
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-S315/HJ-S325
Current(A):16A,32A
Voltage(V):220-380V~
240-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
4h
|
16
|
32 |
3
|
Dimension(mm)
|
axb |
76
|
76
|
cxd |
61
|
61
|
e |
16
|
20
|
f
|
60
|
70
|
g |
5.5 |
5.5 |
h |
46 |
61 |
i |
85 |
95 |
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-S413-4/HJ-S423-4
Current(A):16A,32A
Voltage(V):110-130V~
Protection degree:IP44
|
|
|
|
|
|